Unable to find appropriate service endpoint information in the configuration object - Install Reporting Service extension Dynamics AX

Unable to find appropriate service endpoint information in the configuration object - Install Reporting Service extension Dynamics AX

  • Comments 1

When you try to install Reporting Service Extension on Dynamics AX, you might get the following error.

 "An  occurred during setup of Reporting Services extensions. Reason: Unable to find appropriate service endpoint information in the configuration object"

 

 

Why : Because the BI service is not deployed.

Solutions: try the following.

  1. Open AX > System Adminstration > Setup
                    Services and AIF > Inbound ports.
                                 Click on Activate button (select BI Services) 

 

2. you might want to delete the config file from registry.
           type regedit in the run command (Ctrl+R)
                Go to HKEY_CURRENT_USER\Software\Microsoft\Dynamics\6.0\Configuration\Original
                                    select WCFConfig and delete it

 

Try to install reporting extension now.

     the above registry key will be generated again.

Note: missing end point means a port is not opened for reporting services extension. so activating a port BIServices.(AOT > ServiceGroups > Right Click BIServices> deploy) will help

Leave a Comment
  • Please add 4 and 2 and type the answer here:
  • Post
  • Thanks for posting this solution!