The WLK 1.2 version of the Optical Logo test verifies if the drive reports the following sense codes properly
DESCRIPTION
SENSE KEY
ASC
ASCQ
MEDIUM NOT PRESENT
0x02
0x3A
0x00
MEDIUM NOT PRESENT – TRAY CLOSED
0x01
MEDIUM NOT PRESENT – TRAY OPEN
The test expects the drives to report the tray status in the sense code. The test would fail if these sense codes are not properly reported.
There is an exception to this requirement for the slot type drives. The slot type drives would not have tray so they will not be able to report tray status in the sense code. But the slot drive must report the media loading mechanism type as 0 in the Removable medium feature. The WLK 1.2 version of the optical logo test is not considering this value. But in future, the test would depend on this value to skip the tray status verification test cases for slot type drives.
The following are the loading mechanism type values from MMC5r4.
Mechanism Type
Description
000b
Caddy/Slot type loading mechanism
001b
Tray type loading mechanism
010b
Pop-up type loading mechanism
011b
Reserved
100b
Embedded changer with individually changeable discs
101b
Embedded changer using a magazine mechanism
110b – 111b
The WLK 1.2 version of the optical logo test causes timeout failures for slot type drives, because it relies on the sense code to wait for the tray open/closed operation to complete. The slot type drives will not be able to report the tray status in the sense code. So, the test would cause a time out failure after waiting for 20 seconds. The following errata filter would cover those failures
https://winqual.microsoft.com/EC/ECDetails.aspx?id=1172